High and Low Level Exit Signs
– Photoluminescent [PL] Type
NOTICE: For
complete specification, email: moconnell@activesafety.com
Section
10 14 19 Signage or Section 26 53 [** **] Lighting – Exit
Signs [Section 16 in MF1997] Note
to Spec Writer: “[** **]” indicates decision on
part of Spec Writer
PART
1 GENERAL
1.1
DESCRIPTION
To
the greatest extent possible, in order to install products
with minimal environmental impact, this project will use
non-plastic photo-luminescent type exit signs in both high
and low locations. Plastic exit signs
[photo-luminescent or otherwise] have adverse environmental
consequences and should be avoided. In those areas
where photo-luminescent exit signs can not be used,
non-plastic LED type exit signs will be used.
Radioactive tritium exit signs are expressly prohibited.
Photo-luminescent exit signs are charged from nearby
artificial lighting sources and therefore the facility
lighting plan must be designed, installed and tested to
properly illuminate the PL exit signs. This
Section specifies the engineering, procurement, installation
and testing of photo-luminescent [PL] exit signage for high
and low level applications inside rooms, hallways,
corridors, lobbies, parking garages and other areas.
1.2
RELATED WORK
-
Section
26 51 13 [** **] Interior Lighting Fixtures, Lamps and
Ballasts.
1.3
QUALITY ASSURANCE
-
All
designs and products supplied shall comply with the
following:
1.
NFPA 101: National Fire Protection Association Life Safety
Code, Latest Edition
2.
UL 924: Underwriters Laboratories’ Standard for Emergency
Lighting and Power Equipment.
3.
State and Local Building and Fire Codes
4.
Requirements of local AHJ’s “Authorities having
Jurisdiction”.
B.
Designs, products and installation shall be covered by
GUARANTY, in Section 01 001, GENERAL REQUIREMENTS.
1.4
SUBMITTALS
-
Samples.
Submit a full size sample of each PL exit sign type,
style and color to be furnished. Include samples of
attachment methods. If accepted, samples may be
installed in project.
-
Data
Sheets. Supply the Manufacturer’s technical data
sheets for each PL exit sign type to be furnished.
This information will include the Manufacturer’s UL924
listing documentation.
-
Manufacturer’s
Instructions. Submit Manufacturer’s installation,
operation and maintenance instructions for each PL exit
sign type to be furnished.
-
Installation
Drawings, Schedule and Details. Submit Installation
Drawings and Schedules for each PL exit sign type
indicating where in the building the PL exit signs will
be placed and typical elevation and installation details
for PL sign placement at doors, walls and other
locations.
1.5
APPLICABLE PUBLICATIONS
-
Publications
listed below (including amendments, addenda, revisions,
supplements, and errata) where applicable to PL exit
signage, form a part of this specification.
1.
NFPA 101 Life Safety Code
2.
Underwriter’s Laboratories Standard 924: Emergency
Lighting and Power Equipment
3.
[** State and Local Codes **]
PART
2 PRODUCTS
2.1
HIGH LEVEL PHOTO-LUMINESCENT EXIT SIGNS
-
Manufacturer.
Subject to compliance with specified requirements,
supply products from the following company or as
approved in accordance with Section 01, General
Requirements for Substitutions:
1.
Active Safety Corporation – Series 2002
-
Sign
Viewing Distance. Supply signs with a viewing
distance of 75 feet or more.
|